Brand Name : Micomme
Model Number : T1
Certification : CE
Place of Origin : China
MOQ : 50 units
Price : Negotiable
Payment Terms : L/C, T/T
Supply Ability : 700 units/day
Delivery Time : 10 working days
Packaging Details : 34*24*20CM/unit
Mode : CPAP S, S/T
Pressure range : 4-25cm H2O
Pressure accuracy : ± 0.2 cm H2O
Rise time : 1-6 levels(S,T,S/T)
Humidification : 1-5 levels (113 to 185°F/23 to 85°C)
Mean sound level : ≤30 dB
Micomme COPD solution
Description
Home Non-invasive ventilation (NIV) with bi-level positive airway pressure (BiPAP) is commonly used to treat patients admitted to hospital with acute hypercapnic respiratory failure (AHRF) secondary to an acute exacerbation of chronic obstructive pulmonary disease (AECOPD).
Home Noninvasive positive-pressure ventilation (NPPV) provides ventilatory support without the need for an invasive airway. Interest has emerged in using NPPV to facilitate earlier removal of an endotracheal tube and to decrease complications associated with prolonged intubation.
Application
Emphysema is a lung condition that causes shortness of breath. In people with emphysema, the air sacs in the lungs (alveoli) are damaged. Over time, the inner walls of the air sacs weaken and rupture — creating larger air spaces instead of many small ones.
Lung Parenchyma, it is the portion of the lung involved in gas transfer - the alveoli, alveolar ducts and respiratory bronchioles. However, some authors include other structures and tissues within the definition. There are shortness of breath at rest and aggravated by exertion and dry cough.
Advantage
10 abnormal alarms including low tidal volume.
Real time viewing of multiple treatment data.
Water box fully covered by heating base, anti-spilling and easy to clean.
CPAP mode, the patient has strong spontaneous breathing, and the ventilator provides the same pressure in both inspiratory and expiratory phases to help the patient open the airway.
S mode, the ventilator is triggered by the patient. IPAP and EPAP are provided, and patients control respiratory rate and I/E ratio and inspiratory time autonomously.
S/T mode, when the respiratory rate is less than the backup BPM, the S mode works. When the respiratory rate is more than the backup BPM, the T mode works.
Specifications
Model | T1 |
Mode | CPAP S, S/T |
Pressure range (cmH2O) | 4-25 |
Max. Operation Pressure | 30 cmH2O |
Pressure accuracy | ±0.2 cm H2O |
Rise time | 1-6 levels(S,T,S/T) |
COMF pressure relief | 1-3 levels |
Humidification | 1-5 levels (113 to 185°F/23 to 85°C) |
Ramp time | 0 to 45 min (5-minute increments) |
Data storage capacity | 8G USB disk |
Weight | 1.72 kg |
Mean sound level | ≤30 dB |
Noninvasive CPAP Mode Bipap Machine Ventilator Images |