Hunan Micomme Medical Technology Development Co., Ltd.

Noninvasive CPAP Mode Bipap Machine Ventilator

Brand Name : Micomme

Model Number : T1

Certification : CE

Place of Origin : China

MOQ : 50 units

Price : Negotiable

Payment Terms : L/C, T/T

Supply Ability : 700 units/day

Delivery Time : 10 working days

Packaging Details : 34*24*20CM/unit

Mode : CPAP S, S/T

Pressure range : 4-25cm H2O

Pressure accuracy : ± 0.2 cm H2O

Rise time : 1-6 levels(S,T,S/T)

Humidification : 1-5 levels (113 to 185°F/23 to 85°C)

Mean sound level : ≤30 dB

Contact Now

Micomme COPD solution

Description

Home Non-invasive ventilation (NIV) with bi-level positive airway pressure (BiPAP) is commonly used to treat patients admitted to hospital with acute hypercapnic respiratory failure (AHRF) secondary to an acute exacerbation of chronic obstructive pulmonary disease (AECOPD).

Home Noninvasive positive-pressure ventilation (NPPV) provides ventilatory support without the need for an invasive airway. Interest has emerged in using NPPV to facilitate earlier removal of an endotracheal tube and to decrease complications associated with prolonged intubation.

Application

Emphysema is a lung condition that causes shortness of breath. In people with emphysema, the air sacs in the lungs (alveoli) are damaged. Over time, the inner walls of the air sacs weaken and rupture — creating larger air spaces instead of many small ones.

Lung Parenchyma, it is the portion of the lung involved in gas transfer - the alveoli, alveolar ducts and respiratory bronchioles. However, some authors include other structures and tissues within the definition. There are shortness of breath at rest and aggravated by exertion and dry cough.

Advantage

10 abnormal alarms including low tidal volume.

Real time viewing of multiple treatment data.

Water box fully covered by heating base, anti-spilling and easy to clean.

CPAP mode, the patient has strong spontaneous breathing, and the ventilator provides the same pressure in both inspiratory and expiratory phases to help the patient open the airway.

S mode, the ventilator is triggered by the patient. IPAP and EPAP are provided, and patients control respiratory rate and I/E ratio and inspiratory time autonomously.

S/T mode, when the respiratory rate is less than the backup BPM, the S mode works. When the respiratory rate is more than the backup BPM, the T mode works.

Noninvasive CPAP Mode Bipap Machine Ventilator

Specifications

Model T1
Mode CPAP S, S/T

Pressure range

(cmH2O)

4-25
Max. Operation Pressure 30 cmH2O
Pressure accuracy ±0.2 cm H2O
Rise time 1-6 levels(S,T,S/T)

COMF

pressure relief

1-3 levels
Humidification 1-5 levels (113 to 185°F/23 to 85°C)
Ramp time 0 to 45 min (5-minute increments)

Data storage

capacity

8G USB disk
Weight 1.72 kg
Mean sound level ≤30 dB


Product Tags:

Noninvasive Bipap Machine Ventilator

      

CPAP Mode Bipap Machine Ventilator

      

Noninvasive cpap bipap ventilator

      
Wholesale Noninvasive CPAP Mode Bipap Machine Ventilator from china suppliers

Noninvasive CPAP Mode Bipap Machine Ventilator Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hunan Micomme Medical Technology Development Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)